C1000 Gen 2 vs HomePower 1000 Plus v2 vs OUPES Mega 1
All three store a nominal 1,024 Wh. Start with how much energy you need, then decide whether carrying weight, battery expansion or the electrical limits justify the purchase.
This is a comparison of manufacturer specifications and dated US offers. We have not tested runtime, noise, reliability or customer service. A larger inverter number does not establish longer refrigerator runtime.
Three base units, three different expansion decisions
| Specification | Anker SOLIX C1000 Gen 2 | Jackery HomePower 1000 Plus v2 · White | OUPES Mega 1 |
|---|---|---|---|
| Nominal capacity | 1,024 Wh | 1,024 Wh | 1,024 Wh |
| Total continuous AC | 2,000 W | 1,800 W | 2,000 W |
| Approximate weight | 24.9 lb | 23.8 lb | 27.8 lb |
| Observed base price | Check current price | $779 | $699 |
| Expansion | No battery expansion; do not confuse with original C1000. | Only Battery Pack 2000 Plus v2; not the older 2000 Plus or 1000 Plus packs. | Up to 5,120 Wh total with two optional B2 packs; base listing is 1,024 Wh. |
| Bypass / pass-through | 1,800 W maximum in bypass; lower than battery output. | 15 A maximum, reduced to 12 A after 3 hours; confirm the mode for continuous use. | 2,000 W bypass rating; manual also requires combined input/output below 2,000 W in EPS mode. Verify the exact setup. |
| Availability checked Nov 16 | Unit-only listed available; some solar bundles delayed | White in stock; Black is preorder | Standalone Add to cart available |
Anker SOLIX C1000 Gen 2 technical sourceJackery HomePower 1000 Plus v2 · White technical sourceOUPES Mega 1 technical source
These are three model families, not three bundles. Adding a solar panel does not change stored battery capacity. An expansion pack does, and must be budgeted, carried and connected separately. The table excludes both. Select the exact generation: original C1000, HomePower 1000 v2 without “Plus,” and Mega 1 Lite are different products.
What 1 kWh might mean for your refrigerator
Suppose your meter records 1.2 kWh over a full 24 hours: that is an average 50 W, including cycling during that sample. Add a router averaging 10 W. With an assumed 90% usable battery, 90% inverter efficiency and 10 W battery-side idle draw, the combined draw is about 76.7 W.
Worked example, not a product test
1,024 Wh × 0.90 ÷ (60 W ÷ 0.90 + 10 W) = 12.0 hours
Each of these units gets the same 12.0-hour estimate because the calculator uses the same capacity and assumptions. With appliance demand 20% higher, the estimate drops to 10.2 hours. That sensitivity is an illustration, not a guaranteed range.
For that same load, a 24-hour target calls for about 2.05 kWh nominal in the base case, or 2.40 kWh with 20% higher demand. None of these base units meets that target in this example. A sale price or 2,000 W inverter cannot fix an energy shortfall. Try your numbers in the runtime calculator; if you also need a chest freezer, use the two-appliance worksheet.
Choose according to the constraint you actually have
- Frequent carrying: compare the listed 23.8–27.8 lb base weights against the lift you can comfortably manage. Include the cable and any packs. Handle shape, stairs and balance remain practical questions the weight figure cannot answer.
- One compact, fixed battery: C1000 Gen 2 avoids an expansion decision. Its listed output can be useful for a compatible short, high-power load, but does not add stored energy. Check the price of the selected unit; we have not substituted a solar-bundle price.
- Possible capacity growth: compare the full price and weight of a compatible Jackery or OUPES pack system with buying the needed capacity up front. Do not assume packs with a similar brand name will work. Ask what remains usable if the particular pack is unavailable later.
- A delivery deadline: the Jackery observation is specifically the White unit. The Black version was preorder. Anker’s unit-only availability does not carry over to every panel bundle. Recheck the selected variant and destination before payment.
Battery output and wall-powered bypass are separate checks
When a station stays plugged into a wall, it may pass grid power through to the appliance. That operating mode can have a lower ceiling than battery operation. C1000 Gen 2 lists a 1,800 W bypass maximum. Jackery’s FAQ applies a lower current limit after three hours. OUPES lists 2,000 W bypass but its EPS instructions also constrain combined input and output. Those details are reasons to read the exact manual, not to treat a large inverter label as universal permission.
Refrigerators also stop drawing compressor power between cycles. Confirm that any low-load timeout leaves the AC outlet available long enough for the next start. Manufacturer standby figures do not establish comparable real-world idle losses; we do not plug them into the calculator as if measured under the same conditions.
A short purchase worksheet
- Record appliance energy over representative conditions, plus maximum running demand and evidence about starting demand.
- Choose the exact US generation, color and base-unit contents. Compare delivered cost, return shipping and the current return conditions.
- Confirm individual outlet limits, bypass behavior, required surge duration and timeout settings with the manufacturer.
- Plan a supervised trial with your actual appliances while you can still return the purchase under its terms. Keep refrigerator temperature monitoring separate from the battery display.
If your result fits a smaller existing or borrowed battery, investigate that before buying. If 1 kWh is clearly too small, compare three roughly 3 kWh options or the intermediate 1.5 kWh units in the full catalog.